{"product_id":"pentair-everpure-gro-75en-ro-membrane-cartridge-4002575-high-efficiency-75-gpd-reverse-osmosis-replacement-filter","title":"Pentair Everpure GRO-75EN RO Membrane Cartridge 4002575 – High Efficiency 75 GPD Reverse Osmosis Replacement Filter","description":"\u003ch3 style=\"color: #ff4f5a;\"\u003e*Please call us before placing an order to check the availability of products to avoid unwanted delays\/cancellations.\u003c\/h3\u003e\n\u003ch3 data-end=\"237\" data-start=\"176\" data-section-id=\"1to3kgg\"\u003ePentair Everpure GRO-75EN RO Membrane Cartridge (4002575)\u003c\/h3\u003e\n\u003cp data-end=\"713\" data-start=\"239\"\u003eUpgrade your reverse osmosis system with the Pentair Everpure GRO-75EN RO Membrane Cartridge 4002575, a high-efficiency replacement membrane engineered to deliver exceptional water purification while significantly reducing water waste. Designed for residential and light commercial reverse osmosis systems, this advanced membrane produces up to 75 gallons of purified water per day while achieving industry-leading water recovery rates. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"1086\" data-start=\"715\"\u003eUnlike conventional RO membranes that can waste up to three gallons of water for every gallon purified, the GRO-75EN utilizes Pentair's advanced Thin Layer Composite (TLC) membrane technology to achieve an efficient 1:1 water recovery ratio, helping reduce operating costs and environmental impact without compromising water quality. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"1104\" data-start=\"1088\" data-section-id=\"ycgkk5\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul data-end=\"1710\" data-start=\"1106\"\u003e\n\u003cli data-end=\"1168\" data-start=\"1106\" data-section-id=\"8zxl3i\"\u003eProduces up to 75 gallons of purified water per day (75 GPD)\u003c\/li\u003e\n\u003cli data-end=\"1226\" data-start=\"1169\" data-section-id=\"r2ntqw\"\u003eAdvanced Thin Layer Composite (TLC) membrane technology\u003c\/li\u003e\n\u003cli data-end=\"1269\" data-start=\"1227\" data-section-id=\"1e7xzzl\"\u003eHigh-efficiency 1:1 water recovery ratio\u003c\/li\u003e\n\u003cli data-end=\"1325\" data-start=\"1270\" data-section-id=\"a04diu\"\u003eEncapsulated quick-change design for fast replacement\u003c\/li\u003e\n\u003cli data-end=\"1395\" data-start=\"1326\" data-section-id=\"1k19jrc\"\u003eHelps reduce water consumption compared to traditional RO membranes\u003c\/li\u003e\n\u003cli data-end=\"1443\" data-start=\"1396\" data-section-id=\"52r6g\"\u003eDry-packed membrane design extends shelf life\u003c\/li\u003e\n\u003cli data-end=\"1486\" data-start=\"1444\" data-section-id=\"1iovhmp\"\u003eIncludes integrated permeate check valve\u003c\/li\u003e\n\u003cli data-end=\"1556\" data-start=\"1487\" data-section-id=\"197jlub\"\u003eCompatible with multiple Pentair Everpure and GRO-series RO systems\u003c\/li\u003e\n\u003cli data-end=\"1611\" data-start=\"1557\" data-section-id=\"ko534z\"\u003eDelivers excellent contaminant rejection performance\u003c\/li\u003e\n\u003cli data-end=\"1710\" data-start=\"1612\" data-section-id=\"n0et0v\"\u003eDesigned for residential and light commercial applications \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1740\" data-start=\"1712\" data-section-id=\"nucr17\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2141\" data-start=\"1742\"\u003e\n\u003cthead data-end=\"1769\" data-start=\"1742\"\u003e\n\u003ctr data-end=\"1769\" data-start=\"1742\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"1758\" data-start=\"1742\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"1769\" data-start=\"1758\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2141\" data-start=\"1797\"\u003e\n\u003ctr data-end=\"1817\" data-start=\"1797\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1805\" data-start=\"1797\"\u003eModel\u003c\/td\u003e\n\u003ctd data-end=\"1817\" data-start=\"1805\" data-col-size=\"sm\"\u003eGRO-75EN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1843\" data-start=\"1818\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1832\" data-start=\"1818\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-end=\"1843\" data-start=\"1832\" data-col-size=\"sm\"\u003e4002575\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1878\" data-start=\"1844\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1868\" data-start=\"1844\"\u003eDaily Production Rate\u003c\/td\u003e\n\u003ctd data-end=\"1878\" data-start=\"1868\" data-col-size=\"sm\"\u003e75 GPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1925\" data-start=\"1879\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1895\" data-start=\"1879\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd data-end=\"1925\" data-start=\"1895\" data-col-size=\"sm\"\u003eThin Layer Composite (TLC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1956\" data-start=\"1926\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1945\" data-start=\"1926\"\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd data-end=\"1956\" data-start=\"1945\" data-col-size=\"sm\"\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1986\" data-start=\"1957\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1978\" data-start=\"1957\"\u003eOperating pH Range\u003c\/td\u003e\n\u003ctd data-end=\"1986\" data-start=\"1978\" data-col-size=\"sm\"\u003e4–11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2025\" data-start=\"1987\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2009\" data-start=\"1987\"\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd data-end=\"2025\" data-start=\"2009\" data-col-size=\"sm\"\u003e120°F (49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2057\" data-start=\"2026\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2041\" data-start=\"2026\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd data-end=\"2057\" data-start=\"2041\" data-col-size=\"sm\"\u003eNot Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2084\" data-start=\"2058\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2072\" data-start=\"2058\"\u003eCheck Valve\u003c\/td\u003e\n\u003ctd data-end=\"2084\" data-start=\"2072\" data-col-size=\"sm\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2141\" data-start=\"2085\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2103\" data-start=\"2085\"\u003eMembrane Design\u003c\/td\u003e\n\u003ctd data-end=\"2141\" data-start=\"2103\" data-col-size=\"sm\"\u003eDry Packed Encapsulated Cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-end=\"2180\" data-start=\"2143\"\u003e \u003c\/p\u003e\n\u003ch3 data-end=\"2204\" data-start=\"2182\" data-section-id=\"su5kly\"\u003eCompatible Systems\u003c\/h3\u003e\n\u003cp data-end=\"2262\" data-start=\"2206\"\u003eThe GRO-75EN replacement membrane is commonly used with:\u003c\/p\u003e\n\u003cul data-end=\"2508\" data-start=\"2264\"\u003e\n\u003cli data-end=\"2292\" data-start=\"2264\" data-section-id=\"erffzh\"\u003eEverpure LVRO-75HE Systems\u003c\/li\u003e\n\u003cli data-end=\"2317\" data-start=\"2293\" data-section-id=\"1k0r5hr\"\u003eConserv RO-75S Systems\u003c\/li\u003e\n\u003cli data-end=\"2342\" data-start=\"2318\" data-section-id=\"12l89p5\"\u003eConserv RO-75E Systems\u003c\/li\u003e\n\u003cli data-end=\"2365\" data-start=\"2343\" data-section-id=\"7x6oh4\"\u003eConserv LT-S Systems\u003c\/li\u003e\n\u003cli data-end=\"2411\" data-start=\"2366\" data-section-id=\"tcck8z\"\u003eVarious Pentair GRO reverse osmosis systems\u003c\/li\u003e\n\u003cli data-end=\"2508\" data-start=\"2412\" data-section-id=\"1jpdyqz\"\u003eSelect conventional RO systems when configured correctly \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2546\" data-start=\"2510\" data-section-id=\"kzeehg\"\u003eWhy Choose the GRO-75EN 4002575?\u003c\/h3\u003e\n\u003cp data-end=\"3085\" data-start=\"2548\"\u003eWater filtration performance is only as good as the membrane at the heart of the system. The Pentair Everpure GRO-75EN is designed for users who want premium water quality while minimizing water waste. Its high-efficiency design can dramatically reduce wastewater production compared to traditional RO membranes, making it an excellent choice for environmentally conscious homes, coffee shops, foodservice operations, and commercial applications that rely on consistent, high-quality purified water. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"3106\" data-start=\"3087\" data-section-id=\"7zsklc\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul data-end=\"3280\" data-start=\"3108\"\u003e\n\u003cli data-end=\"3161\" data-start=\"3108\" data-section-id=\"18467yg\"\u003e1 × Pentair Everpure GRO-75EN RO Membrane Cartridge\u003c\/li\u003e\n\u003cli data-end=\"3195\" data-start=\"3162\" data-section-id=\"92astq\"\u003eIntegrated permeate check valve\u003c\/li\u003e\n\u003cli data-end=\"3280\" data-start=\"3196\" data-section-id=\"1huts8a\"\u003eFactory-sealed dry-packed membrane cartridge\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pentair Everpure","offers":[{"title":"Default Title","offer_id":47748714135715,"sku":"4002575","price":179.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0527\/8885\/4947\/files\/4002575_1.png?v=1780845367","url":"https:\/\/www.aromaespresso.ca\/products\/pentair-everpure-gro-75en-ro-membrane-cartridge-4002575-high-efficiency-75-gpd-reverse-osmosis-replacement-filter","provider":"Aroma Espresso Services","version":"1.0","type":"link"}